Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 18.554
Filtrar
1.
Sci Rep ; 14(1): 8364, 2024 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600312

RESUMO

This study retrospectively assessed radiographic outcomes and risk factors associated with non-union in femoral shaft fragmentary segmental fractures (AO/OTA 32C3) treated with reamed antegrade intra-medullary nailing. Radiological outcomes, including union and alignment, were evaluated. The risk factors for non-union were investigated, including demographics and treatment-related characteristics, such as the number of interlocking screws, segmentation length, main third fragment length, distance of the main third fragment, width ratio and exposed nail length in one cortex from immediate post-operative radiographs. Multivariate logistic regression was used for statistical analysis. Among 2295 femoral shaft fracture patients from three level-1 trauma centers, 51 met the inclusion criteria. The radiological union was achieved in 37 patients (73%) with a mean union time of 10.7 ± 4.8 months. The acceptable axial alignment was observed in 30 patients (59%). Multiple logistic regression analysis identified only exposed nail length as a significant risk factor for non-union (odds ratio: 1.599, p = 0.003) and the cut-off value was 19.1 mm (sensitivity, 0.786; specificity, 0.811). The study revealed high rates of non-union (27%) and malalignment (41%). Therefore, patients who underwent intramedullary nailing with an exposed nail length greater than 19.1 mm or about twice the nail diameter should be cautioned of the potential non-union.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Humanos , Fixação Intramedular de Fraturas/efeitos adversos , Estudos Retrospectivos , Pinos Ortopédicos/efeitos adversos , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/etiologia , Radiografia , Resultado do Tratamento , Consolidação da Fratura
2.
Zhongguo Gu Shang ; 37(4): 406-10, 2024 Apr 25.
Artigo em Chinês | MEDLINE | ID: mdl-38664213

RESUMO

OBJECTIVE: To investigate the efficacy of antibiotic cement column combined with iliac bone graft in the treatment of open fracture with bone defect of distal femur. METHODS: From October 2014 to March 2021, 16 patients of open fracture bone defect of distal femur were treated with antibiotic bone cement column and iliac bone graft, including 12 males and 4 females. The age ranged from 28 to 68 years old. There were 11 cases of traffic accident injury, 5 cases of falling injury, 3 cases as Gustilo type Ⅰ, 5 cases as type Ⅱ and 8 cases as type ⅢA. AO classification was used:9 cases of C2 type and 7 cases of C3 type. The time from injury to final bone grafting ranged from 4 to 119 days. The length of bone defect ranged from 2 to10 cm. Fractures healing time, complications and knee function Merchan score were recorded. RESULTS: All the 16 patients were followed up from 9 to 29 months. The incisions of 16 patients healed in one stage without postoperative infection, plate fracture, limb shortening and valgus and varus deformity. The healing time randed from 4 to 10 months . Knee joint function according to the Merchant scoring standard, showed that 8 cases were excellent, 4 cases were good, 3 cases were fair, and 1 case was poor. CONCLUSION: The use of antibiotic bone cement column combined with iliac bone graft in the treatment of open and complex bone defects of distal femur is an effective surgical method to prevent infection, assist fracture reduction, increase fixation strength and significantly reduce the amount of bone grafting.


Assuntos
Antibacterianos , Cimentos Ósseos , Transplante Ósseo , Fraturas Expostas , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Transplante Ósseo/métodos , Idoso , Fraturas Expostas/cirurgia , Antibacterianos/administração & dosagem , Fêmur/cirurgia , Fraturas do Fêmur/cirurgia
3.
JBJS Case Connect ; 14(2)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38579021

RESUMO

CASE: A 51-year-old man and 64-year-old woman with bilateral cruciate-retaining total knee arthroplasties (CR-TKAs) who sustained unilateral periprosthetic distal femur fractures above their CR-TKA and experienced knee instability secondary to an iatrogenic posterior-cruciate-ligament (posterior cruciate ligament [PCL]) injury from retrograde intramedullary nailing. Both patients recovered knee stability after undergoing revision surgery. CONCLUSION: Many CR-TKA designs have sufficient medial-lateral intercondylar distance to place a retrograde nail, femoral components with a relatively posterior transition from the trochlear groove to the intercondylar box will necessitate a nail starting point closer to the PCL origin. This may contribute to iatrogenic postoperative knee instability for patients with CR-TKA designs.


Assuntos
Fraturas Femorais Distais , Fraturas do Fêmur , Fixação Intramedular de Fraturas , Ligamento Cruzado Posterior , Feminino , Humanos , Masculino , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/efeitos adversos , Doença Iatrogênica , Ligamento Cruzado Posterior/cirurgia , Pessoa de Meia-Idade
4.
Acta Ortop Mex ; 38(1): 10-14, 2024.
Artigo em Espanhol | MEDLINE | ID: mdl-38657146

RESUMO

INTRODUCTION: health promotion policy requires the identification of barriers to the adoption of public policies. Paraguay's national healthcare system is inequitable, expensive, and inefficient. The Ministry of Public Health and Social Welfare (MSPyBS) is the entity responsible for covering the needs of a significant portion of the population. In January 2022, the MSPyBS financed the purchase of titanium elastic nails through a National Public Tender for Osteosynthesis Materials (LPN 02/22) to provide them for free in the pediatric service. Using research as a tool, we seek to analyze the impact of the implementation of LPN 02/22 at the Trauma Hospital, believing that this action would help streamline administrative and bureaucratic processes, making them more efficient with the assistance of the hospital's human resources. MATERIAL AND METHODS: a retrospective, analytical, and comparative study conducted at a high-complexity trauma center in Asunción, Paraguay. Patients aged 4 to 14 years with an indication for stabilization with elastic nails were included. Demographic data, the mechanism of injury, time elapsed from hospital arrival to surgical treatment, length of hospital stay, and the average hospital cost were analyzed based on the daily expense of pediatric patient hospitalization. RESULTS: 52 patients, divided into 25 cases in 2021 before implementation and 27 cases after implementation. The time elapsed from hospital arrival to definitive treatment was six days in the pre-implementation period, with an average stay from admission to discharge of 7.4 days. After implementation, the time from hospital arrival to definitive treatment was 4.3 days, and the average discharge time for the Post group was six days. The potential savings per patient amount to 332 dollars, offset by the institution's implant supply cost of 197 dollars, resulting in an approximate savings of 135 dollars per patient for the ministry. CONCLUSIONS: we view the implementation of free titanium elastic nails for pediatric femur fracture patients positively. We encourage the institution to continue with similar policies and strive to achieve even greater benefits for users.


INTRODUCCIÓN: la política de promoción de la salud requiere la identificación de los obstáculos para la adopción de políticas públicas. El sistema nacional de salud de Paraguay es inequitativo, caro e ineficiente. El Ministerio de Salud Pública y Bienestar Social (MSPyBS) es el ente que cubre las necesidades de gran parte de la población. El MSPyBS en Enero del 2022 financió, mediante la Licitación Pública Nacional de Materiales de Osteosíntesis (LPN 02/22), la compra de clavos elásticos de titanio para disponer de su uso gratuito en el Servicio de Pediatría; usando a la investigación como herramienta, buscamos analizar el impacto de la implementación de la LPN 02/22 en el Hospital de Trauma, creyendo que esta acción ayudaría a dinamizar los procesos administrativos y burocráticos, haciéndolos más eficientes con la ayuda de los recursos humanos del hospital. MATERIAL Y MÉTODOS: estudio retrospectivo, analítico y comparativo, realizado en un centro de trauma de alta complejidad de Asunción, Paraguay. Fueron incluidos los pacientes con edad comprendidas entre cuatro y 14 años, con indicación de estabilización con clavos elásticos. Se analizaron los datos demográficos, el mecanismo de trauma, el tiempo transcurrido desde la llegada al hospital hasta el tratamiento quirúrgico, así como el tiempo de estadía hospitalaria. Se evaluó el costo hospitalario promedio, basados en el gasto diario de la internación de un paciente pediátrico. RESULTADOS: cincuenta y dos pacientes, separados en 25 casos en el 2021 previo a la implementación y 27 casos posterior a la implementación. El tiempo transcurrido desde la llegada al hospital hasta el tratamiento definitivo fue de seis días para la etapa previa a la implementación; el promedio desde el ingreso hasta el alta fue de 7.4 días. Desde la implementación se tuvo un transcurso de 4.3 días desde la llegada al hospital hasta el tratamiento definitivo. El egreso del grupo Post tuvo un promedio de seis días. El ahorro probable en relación con cada paciente es de 332 dólares; a esto debemos contrarrestar el monto que paga la institución para la provisión del implante (197 dólares), por lo que el ahorro del ministerio sería de aproximadamente 135 dólares por cada paciente. CONCLUSIONES: vemos como positiva la implementación de la gratuidad de los clavos elásticos de titanio en los pacientes en edad pediátrica con fractura de fémur. Alentamos a la institución a seguir con políticas similares y tratar de lograr mayores beneficios para los usuarios.


Assuntos
Fraturas do Fêmur , Humanos , Criança , Estudos Retrospectivos , Adolescente , Pré-Escolar , Feminino , Masculino , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/economia , Paraguai , Tempo de Internação/estatística & dados numéricos , Pinos Ortopédicos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/economia , Fixação Interna de Fraturas/instrumentação , Custos Hospitalares/estatística & dados numéricos , Centros de Traumatologia/organização & administração , Titânio
5.
Ortop Traumatol Rehabil ; 26(1): 369-373, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38646902

RESUMO

BACKGROUND: Pediatric femoral fractures are common in emergency rooms, with treatment options varying by age. This study compares elastic stable intramedullary nailing (ESIN) and plate fixation for diaphyseal femoral fractures in children aged 5-10. MATERIAL AND METHODS: Conducted at Al-Kindi Teaching Hospital, Baghdad, from December 2017 to December 2019, this prospective study included 32 children with closed transverse diaphyseal femoral fractures. Patients were divided into two groups: 16 treated with ESIN (Group 1) and 16 with plate fixation (Group 2). Criteria excluded comminuted, open, or pathological fractures. RESULTS: Group 1 had a mean age of 7.1 years and weight of 23.7 kg; Group 2 had a mean age of 7.8 years and weight of 30.9 kg. ESIN resulted in shorter operative times (58.4 minutes), earlier weight-bearing, and quicker fracture union (8.8 weeks) compared to plate fixation (76.3 minutes, 11.9 weeks). Blood loss was significantly less in Group 1 (32.8 ml) versus Group 2 (205.0 ml). No significant differences in wound healing or leg length discrepancies were observed. CONCLUSIONS: 1. Our study indicates a preference for Elastic Stable Intramedullary Nailing (ESIN) over plate fixation for pediatric femoral shaft fractures in children aged 5-10 years. 2. ESIN is associated with shorter operative times and faster commencement of weight-bearing, critical in pediatric recovery. 3. While ESIN is generally preferable, plate fixation may be better suited in certain clinical scenarios, emphasizing the importance of personalized treatment. 4. Based on our findings, ESIN is recommended for treating transverse diaphyseal femur fractures in the specified pediatric age group. 5. Recommends further studies, including randomized controlled trials, for a more comprehensive understanding of these treatments' long-term outcomes.


Assuntos
Placas Ósseas , Fraturas do Fêmur , Fixação Intramedular de Fraturas , Humanos , Criança , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/instrumentação , Fraturas do Fêmur/cirurgia , Estudos Prospectivos , Feminino , Masculino , Pré-Escolar , Resultado do Tratamento , Consolidação da Fratura
6.
Int J Mol Sci ; 25(7)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38612562

RESUMO

Fracture healing is a complex series of events that requires a local inflammatory reaction to initiate the reparative process. This inflammatory reaction is important for stimulating the migration and proliferation of mesenchymal progenitor cells from the periosteum and surrounding tissues to form the cartilaginous and bony calluses. The proinflammatory cytokine interleukin (IL)-17 family has gained attention for its potential regenerative effects; however, the requirement of IL-17 signaling within mesenchymal progenitor cells for normal secondary fracture healing remains unknown. The conditional knockout of IL-17 receptor a (Il17ra) in mesenchymal progenitor cells was achieved by crossing Il17raF/F mice with Prx1-cre mice to generate Prx1-cre; Il17raF/F mice. At 3 months of age, mice underwent experimental unilateral mid-diaphyseal femoral fractures and healing was assessed by micro-computed tomography (µCT) and histomorphometric analyses. The effects of IL-17RA signaling on the osteogenic differentiation of fracture-activated periosteal cells was investigated in vitro. Examination of the intact skeleton revealed that the conditional knockout of Il17ra decreased the femoral cortical porosity but did not affect any femoral trabecular microarchitectural indices. After unilateral femoral fractures, Il17ra conditional knockout impacted the cartilage and bone composition of the fracture callus that was most evident early in the healing process (day 7 and 14 post-fracture). Furthermore, the in vitro treatment of fracture-activated periosteal cells with IL-17A inhibited osteogenesis. This study suggests that IL-17RA signaling within Prx1+ mesenchymal progenitor cells can influence the early stages of endochondral ossification during fracture healing.


Assuntos
Fraturas do Fêmur , Células-Tronco Mesenquimais , Animais , Camundongos , Consolidação da Fratura , Osteogênese , Microtomografia por Raio-X , Inflamação
7.
PLoS One ; 19(4): e0298086, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38626076

RESUMO

Non-thermal atmospheric-pressure plasma (NTAPP) is attracting widespread interest for use in medical applications. The tissue repair capacity of NTAPP has been reported in various fields; however, little is known about its effect on fracture healing. Non-union or delayed union after a fracture is a clinical challenge. In this study, we aimed to investigate how NTAPP irradiation promotes fracture healing in a non-union fracture model and its underlying mechanism, in vitro and in vivo. For the in vivo study, we created normal and non-union fracture models in LEW/SsNSlc rats to investigate the effects of NTAPP. To create a fracture, a transverse osteotomy was performed in the middle of the femoral shaft. To induce the non-union fracture model, the periosteum surrounding the fracture site was cauterized after a normal fracture model was created. The normal fracture model showed no significant difference in bone healing between the control and NTAPP-treated groups. The non-union fracture model demonstrated that the NTAPP-treated group showed consistent improvement in fracture healing. Histological and biomechanical assessments confirmed the fracture healing. The in vitro study using pre-osteoblastic MC3T3-E1 cells demonstrated that NTAPP irradiation under specific conditions did not reduce cell proliferation but did enhance osteoblastic differentiation. Overall, these results suggest that NTAPP is a novel approach to the treatment of bone fractures.


Assuntos
Fraturas do Fêmur , Fraturas Ósseas , Gases em Plasma , Ratos , Animais , Consolidação da Fratura , Gases em Plasma/farmacologia , Gases em Plasma/uso terapêutico , Diferenciação Celular , Proliferação de Células , Fraturas do Fêmur/cirurgia
8.
Georgian Med News ; (347): 149-150, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38609132

RESUMO

Traditionally, it was believed that both proximal and distal locking are essential for achieving stability during intra-medullary fixation for extra-capsular hip fractures. However, recent literature has presented varying perspectives on the necessity of distal locking. Distal locking plays a significant role in managing hip fractures with uncertainties regarding longitudinal and rotational stability. This includes cases of comminuted intertrochanteric fractures with subtrochanteric extension, reverse oblique and high oblique fractures, broad medullary canals, comminution of the lateral wall, diaphyseal fractures, and large posteromedial fragments extending below the level of the lesser trochanter. In stable pertrochanteric fractures, with the lag screw passing through the lateral cortex of the distal fragment, may not require a distal locking screw. Distal locking has been associated with potential complications, including irritation of the fascia lata, prolonged operation time, increased radiation exposure, greater blood loss, implant loosening, secondary femoral stress fractures, and damage to the femoral artery. Thus, although distal locking is of doubtful significance in stable pertrochanteric fractures it is essential in unstable fracture patterns.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Fraturas do Quadril , Humanos , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Parafusos Ósseos , Artéria Femoral
9.
BMC Musculoskelet Disord ; 25(1): 271, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589829

RESUMO

BACKGROUND: Single limb support phase of the gait-cycle in patients who are treated for a pertrochanteric fracture is characterized by transversal loads acting on the lag screw, tending to block its dynamization. If the simultaneous axial force overcomes transversal loads of the sliding screw, the dynamization can still occur. METHODS: Biomechanical investigation was performed for three types of dynamic implants: Gamma Nail, and two types of Selfdynamizable Internal Fixators (SIF) - SIF-7 (containing two 7 mm non-cannulated sliding screws), and SIF-10 (containing one 10 mm cannulated sliding screw). Contact surface between the stem and the sliding screws is larger in SIF implants than in Gamma Nail, as the stem of Gamma Nail is hollow. A special testing device was designed for this study to provide simultaneous application of a controlled sliding screws bending moment and a controlled transversal load on sliding screws (Qt) without using of weights. Using each of the implants, axial forces required to initiate sliding screws dynamization (Qa) were applied and measured using a tensile testing machine, for several values of sliding screws bending moment. Standard least-squares method was used to present the results through the linear regression model. RESULTS: Positive correlation between Qt and Qa was confirmed (p < 0.05). While performing higher bending moments in all the tested implants, Qa was higher than it could be provided by the body weight. It was the highest in Gamma Nail, and the lowest in SIF-10. CONCLUSIONS: A larger contact surface between a sliding screw and stem results in lower forces required to initiate dynamization of a sliding screw. Patients treated for a pertrochanteric fracture by a sliding screw internal fixation who have longer femoral neck or higher body weight could have different programme of early postoperative rehabilitation than lighter patients or patients with shorter femoral neck.


Assuntos
Parafusos Ósseos , Fraturas do Fêmur , Humanos , Parafusos Ósseos/efeitos adversos , Fenômenos Biomecânicos , Fixadores Internos , Fixação Interna de Fraturas , Fraturas do Fêmur/etiologia , Peso Corporal
10.
J Orthop Traumatol ; 25(1): 23, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653863

RESUMO

BACKGROUND: The exact positioning of the cephalomedullary (CM) nail entry point for managing femoral fractures remains debatable, with significant implications for fracture reduction and postoperative complications. This study aimed to explore the variability in the selection of the entry point among trauma surgeons, hypothesizing potential differences and their association with surgeon experience. METHODS: In this prospective multicenter study, 16 participants, ranging from residents to senior specialists, partook in a simulation wherein they determined the optimal entry point for the implantation of a proximal femoral nail antirotation (PFN-A; DePuy Synthes) in various femora. The inter- and intra-observer variability was calculated, along with comprehensive descriptive statistical analysis, to assess the variability in entry point selection and the impact of surgeon experience. RESULTS: In this study, the mean distance from the selected entry points to the calculated mean entry point was 3.98 mm, with a smaller distance observed among surgeons with more than 500 implantations (ANOVA, p = 0.050). Intra-surgeon variability for identical femora averaged at 5.14 mm, showing no significant differences across various levels of surgical experience or training. Notably, 13.6% of selected entry points would not allow a proper intramedullary positioning of the implant, thereby rendering anatomical repositioning unfeasible. Among these impossible entry points, a significant skew towards anterior placement was observed (70.6% of the impossible entry points), with a smaller fraction being overly lateral (27.5%) or medial (13.7%). On a patient level, the impossibility rate varied widely from 0 to 35% among the different femora examined, with a significantly higher rate seen in younger patients (mean age 55.02 versus 60.32; t-test for independent samples, p = 0.04). CONCLUSIONS: Significant variations exist in surgeons' selection of entry points for proximal femoral nailing, underscoring the task's complexity. Experience does not prevent the choice of unfeasible entry points, emphasizing the inadequacy of a universal approach and pointing towards the necessity for a patient-specific strategy for improved outcomes. TRIAL REGISTRATION NUMBER: DRKS00032465.


Assuntos
Pinos Ortopédicos , Fraturas do Fêmur , Fixação Intramedular de Fraturas , Humanos , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/instrumentação , Estudos Prospectivos , Fraturas do Fêmur/cirurgia , Competência Clínica , Variações Dependentes do Observador , Feminino , Masculino
11.
J Am Acad Orthop Surg ; 32(9): 373-380, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38639649

RESUMO

Pediatric femur fractures in children aged 5 to 11 years are typically classified as length-stable versus length-unstable. For length-stable fracture patterns, there is frequent consensus among pediatric orthopaedic specialists regarding the appropriateness of flexible intramedullary nails, submuscular plates (SMP), or lateral-entry rigid intramedullary nails (LE-RIMN). With length-unstable fracture patterns, however, the decision is more complex. Age, weight, fracture pattern, fracture location, surgical technique, surgeon experience, several implant-specific details, and additional factors are all important when choosing between flexible intramedullary nail, SMP, and LE-RIMN. These familiar methods of fixation may all be supported by conflicting and sometimes heterogeneous data. When planning to treat length-unstable fractures in young children, surgeons should understand evidence-based details associated with each implant and how each patient-specific scenario affects perioperative decisions.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Humanos , Criança , Pré-Escolar , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/métodos , Pinos Ortopédicos , Placas Ósseas , Fêmur/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
12.
Eur Rev Med Pharmacol Sci ; 28(4): 1375-1383, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38436170

RESUMO

OBJECTIVE: The aim of this study was to compare the difference between proximal femoral bionic nail (PFBN) and hip replacement (HR) for femoral intertrochanteric fracture. MATERIALS AND METHODS: A retrospective analysis of the differences in operative time, length of stay, postoperative Harris score, and postoperative mortality between patients with femoral intertrochanteric fracture treated by PFBN and HR admitted to Jinzhai County People's Hospital from October 2020 to September 2022 was performed. RESULTS: A total of 56 patients with femoral intertrochanteric fracture, 26 with PFBN and 30 with HR, were included in the study. There were no differences in the length of surgery, pre- and post-operative hemoglobin, or post-operative Harris score at 3 months between the two groups. Compared to the HR group, the PFBN group had a lower total cost, shorter hospital stays, and lower mortality but a longer ambulation time, with a difference of 3.36 weeks. CONCLUSIONS: PFBN may be a promising new treatment for femoral intertrochanteric fracture.


Assuntos
Fraturas do Fêmur , Fraturas do Quadril , Humanos , Biônica , Estudos Retrospectivos , Fraturas do Quadril/cirurgia , Fêmur
13.
Bone Joint J ; 106-B(2): 158-165, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38425310

RESUMO

Aims: Periprosthetic fractures (PPFs) around the knee are challenging injuries. This study aims to describe the characteristics of knee PPFs and the impact of patient demographics, fracture types, and management modalities on in-hospital mortality. Methods: Using a multicentre study design, independent of registry data, we included adult patients sustaining a PPF around a knee arthroplasty between 1 January 2010 and 31 December 2019. Univariate, then multivariable, logistic regression analyses were performed to study the impact of patient, fracture, and treatment on mortality. Results: Out of a total of 1,667 patients in the PPF study database, 420 patients were included. The in-hospital mortality rate was 6.4%. Multivariable analyses suggested that American Society of Anesthesiologists (ASA) grade, history of peripheral vascular disease (PVD), history of rheumatic disease, fracture around a loose implant, and cerebrovascular accident (CVA) during hospital stay were each independently associated with mortality. Each point increase in ASA grade independently correlated with a four-fold greater mortality risk (odds ratio (OR) 4.1 (95% confidence interval (CI) 1.19 to 14.06); p = 0.026). Patients with PVD have a nine-fold increase in mortality risk (OR 9.1 (95% CI 1.25 to 66.47); p = 0.030) and patients with rheumatic disease have a 6.8-fold increase in mortality risk (OR 6.8 (95% CI 1.32 to 34.68); p = 0.022). Patients with a fracture around a loose implant (Unified Classification System (UCS) B2) have a 20-fold increase in mortality, compared to UCS A1 (OR 20.9 (95% CI 1.61 to 271.38); p = 0.020). Mode of management was not a significant predictor of mortality. Patients managed with revision arthroplasty had a significantly longer length of stay (median 16 days; p = 0.029) and higher rates of return to theatre, compared to patients treated nonoperatively or with fixation. Conclusion: The mortality rate in PPFs around the knee is similar to that for native distal femur and neck of femur fragility fractures. Patients with certain modifiable risk factors should be optimized. A national PPF database and standardized management guidelines are currently required to understand these complex injuries and to improve patient outcomes.


Assuntos
Artroplastia do Joelho , Fraturas do Fêmur , Fraturas Periprotéticas , Doenças Reumáticas , Adulto , Humanos , Fraturas Periprotéticas/etiologia , Articulação do Joelho/cirurgia , Joelho/cirurgia , Artroplastia do Joelho/efeitos adversos , Fraturas do Fêmur/cirurgia , Doenças Reumáticas/etiologia , Doenças Reumáticas/cirurgia , Estudos Retrospectivos , Reoperação
14.
Sci Rep ; 14(1): 5536, 2024 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-38448630

RESUMO

We aimed to establish a new method of obtaining femur anteroposterior radiographs from live rats. We used five adult male Sprague-Dawley rats and created a femoral fracture model with an 8 mm segmental fragment. After the surgery, we obtained two femoral anteroposterior radiographs, a novel overhead method, and a traditional craniocaudal view. We obtained the overhead method three times, craniocaudal view once, and anteroposterior radiograph of the isolated femoral bone after euthanasia. We compared the overhead method and craniocaudal view with an isolated femoral anteroposterior view. We used a two-sample t-test and intraclass correlation coefficient (ICC) to estimate the intra-observer reliability. The overhead method had significantly smaller differences than the craniocaudal view for nail length (1.53 ± 1.26 vs. 11.4 ± 3.45, p < 0.001, ICC 0.96) and neck shaft angle (5.82 ± 3.8 vs. 37.8 ± 5.7, p < 0.001, ICC 0.96). No significant differences existed for intertrochanteric length/femoral head diameter (0.23 ± 0.13 vs. 0.23 ± 0.13, p = 0.96, ICC 0.98) or lateral condyle/medial condyle width (0.15 ± 0.16 vs. 0.13 ± 0.08, p = 0.82, ICC 0.99). A fragment displacement was within 0.11 mm (2.4%). The overhead method was closer to the isolated femoral anteroposterior view and had higher reliability.


Assuntos
Fraturas do Fêmur , Masculino , Animais , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Fraturas do Fêmur/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Espinhas Dendríticas
15.
Acta Chir Orthop Traumatol Cech ; 91(1): 44-51, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38447564

RESUMO

PURPOSE OF THE STUDY: Surgical options for paediatric femoral fractures include fl exible intramedullary nailing (FIN), plating, and external fi xators. Length unstable fractures are usually spiral, long oblique, or comminuted and are often associated with > 2 cm of shortening. The purpose of this study was to see whether FIN is effective for managing unstable femur fractures in children. MATERIAL AND METHODS: An electronic literature search was performed up to 25 February 2022 in Cochrane Library, PubMed, and Embase databases using a combination of MeSH search terms and keywords related to the population (e.g., "child" AND "diaphyses" AND "femur"), and intervention (e.g., "nail" OR "ESIN"). The data extracted included the study details, Demographic data, surgical details, postoperative immobilization, complications, and outcome. RESULTS: Eight studies with a total sample size of 369 patients were reviewed. The mean operative time, blood loss, and length of stay in the hospital were 67.62±12.32 minutes, 33.82±16.82 ml, and 4.9±1.27 days, respectively. The results were excellent in 61.92% of the patients, satisfactory in 32.61%, and poor in 5.43%. 4.54% of patients had major complications requiring reoperation and 32.46% of patients had minor complications. the most common complication was nail prominence seen in 26.30% of patients. Locked Ender's nail was associated with the least reoperation, malunion, and LLD rate compared to other types of FIN. CONCLUSIONS: FIN along with a single walking spica cast is a good choice in all forms of paediatric femoral fracture patterns allowing proper alignment and rotation. Locked Ender's nail is safe and effective for managing unstable paediatric femur fracture. KEY WORDS: pediatric femur fracture, length unstable, fl exible intramedullary nailing, submuscular plating, Flynn criterion.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Humanos , Criança , Fêmur , Extremidade Inferior , Fixadores Internos , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/efeitos adversos
16.
Acta Biomater ; 178: 320-329, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38479677

RESUMO

Stress-induced corrosion impairs the mechanical integrity of magnesium (Mg) and its alloys as potential orthopedic implants. Although there has been extensive work reporting the effects of stress on Mg corrosion in vitro, the geometric design principles of the Mg-based orthopedic devices still remain largely unknown. In this work, a numerical simulation model mimicking fractured bone fixation and surgical animal models were applied to investigate the effects of the geometric design of Mg screws on the stress distribution and the stress-induced degradation behavior. Finite element (FE) analysis was used for calculation of stress concentrations around the Mg screws, with different thread type, thread pitch, and thread width. Afterward, the Mg screws of the pre-optimization and post-optimization groups exhibiting the highest and lowest stress concentrations, respectively, were implanted in the fractured distal femora and back subcutaneous tissue of rabbits. Encouragingly, there was a significant difference between the pre-optimization and the post-optimization groups in the degradation rate of the stressed screw parts located around the fracture line. Interestingly, there was no significant difference between the two groups in the degradation rate of the non-stressed screw parts. Consistently, the Mg screw post-optimization exhibited a significantly lower degradation rate than that pre-optimization in the back subcutaneous implantation model, which generated stress in the whole screw body. The alteration in geometric design did not affect the corrosion rate of the Mg screws in an immersion test without load applied. Importantly, an accelerated new bone formation with less fibrous encapsulation around the screws was observed in the Mg group post-optimization relative to the Mg group pre-optimization and the poly (lactic acid) group. Geometry optimization may be a promising strategy to reduce stress-induced corrosion in Mg-based orthopedic devices. STATEMENT OF SIGNIFICANCE: Stress concentrations influence corrosion characteristics of magnesium (Mg)-based implants. The geometric design parameters, including thread type, thread pitch, and thread width of the Mg screws, were optimized through finite element analysis to reduce stress concentrations in a fractured model. The Mg screws with triangular thread type, 2.25 mm pitch, and 0.3 mm thread width, exhibiting the lowest maximum von Mises stress, showed a significant decrease in the volume loss relative to the Mg screws pre-optimization. Compared with the Mg screw pre-optimization and the poly(lactic acid) screw, the Mg screw post-optimization favored new bone formation while inhibiting fibrous encapsulation. Collectively, optimization in the geometric design is a promising approach to reduce stress-induced corrosion in Mg-based implants.


Assuntos
Fraturas do Fêmur , Consolidação da Fratura , Animais , Coelhos , Magnésio/farmacologia , Corrosão , Parafusos Ósseos , Fraturas do Fêmur/cirurgia , Análise de Elementos Finitos , Fenômenos Biomecânicos
17.
Cells ; 13(6)2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38534368

RESUMO

Fracture callus formation is a dynamic stage of bone activity and repair with precise, spatially localized gene expression. Metastatic breast cancer impairs fracture healing by disrupting bone homeostasis and imparting an altered genomic profile. Previous sequencing techniques such as single-cell RNA and in situ hybridization are limited by missing spatial context and low throughput, respectively. We present a preliminary approach using the Visium CytAssist spatial transcriptomics platform to provide the first spatially intact characterization of genetic expression changes within an orthopedic model of impaired fracture healing. Tissue slides prepared from BALB/c mice with or without MDA-MB-231 metastatic breast cancer cells were used. Both unsupervised clustering and histology-based annotations were performed to identify the hard callus, soft callus, and interzone for differential gene expression between the wild-type and pathological fracture model. The spatial transcriptomics platform successfully localized validated genes of the hard (Dmp1, Sost) and soft callus (Acan, Col2a1). The fibrous interzone was identified as a region of extensive genomic heterogeneity. MDA-MB-231 samples demonstrated downregulation of the critical bone matrix and structural regulators that may explain the weakened bone structure of pathological fractures. Spatial transcriptomics may represent a valuable tool in orthopedic research by providing temporal and spatial context.


Assuntos
Calo Ósseo , Fraturas do Fêmur , Camundongos , Animais , Calo Ósseo/metabolismo , Calo Ósseo/patologia , Fraturas do Fêmur/patologia , Consolidação da Fratura , Perfilação da Expressão Gênica
18.
Bone Joint J ; 106-B(4): 344-351, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555949

RESUMO

Aims: Revision total hip arthroplasty in patients with Vancouver type B3 fractures with Paprosky type IIIA, IIIB, and IV femoral defects are difficult to treat. One option for Paprovsky type IIIB and IV defects involves modular cementless, tapered, revision femoral components in conjunction with distal interlocking screws. The aim of this study was to analyze the rate of reoperations and complications and union of the fracture, subsidence of the stem, mortality, and the clinical outcomes in these patients. Methods: A total of 46 femoral components in patients with Vancouver B3 fractures (23 with Paprosky type IIIA, 19 with type IIIB, and four with type IV defects) in 46 patients were revised with a transfemoral approach using a modular, tapered, cementless revision Revitan curved femoral component with distal cone-in-cone fixation and prospectively followed for a mean of 48.8 months (SD 23.9; 24 to 112). The mean age of the patients was 80.4 years (66 to 100). Additional distal interlocking was also used in 23 fractures in which distal cone-in-cone fixation in the isthmus was < 3 cm. Results: One patient (2.2%) died during the first postoperative year. After six months, 43 patients (93.5%) had osseous, and three had fibrous consolidation of the fracture and the bony flap, 42 (91.3%) had bony ingrowth and four had stable fibrous fixation of the stem. No patient had radiolucency around the interlocking screws and no screw broke. One patient had non-progressive subsidence and two had a dislocation. The mean Harris Hip Score increased from of 57.8 points (SD 7.9) three months postoperatively to 76.1 points (SD 10.7) 24 months postoperatively. Conclusion: The 2° tapered, fluted revision femoral component with distal cone-in-cone-fixation, combined with additional distal interlocking in patients with bony deficiency at the isthmus, led to reproducibly good results in patients with a Vancouver B3 fracture and Paprosky type IIIA, IIIB, and IV defects with regard to union of the fracture, subsidence or loosening of the stem, and clinical outcomes.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Fraturas Periprotéticas/cirurgia , Fraturas Periprotéticas/etiologia , Prótese de Quadril/efeitos adversos , Resultado do Tratamento , Desenho de Prótese , Reoperação/métodos , Fraturas do Fêmur/cirurgia , Estudos Retrospectivos
19.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(3): 290-297, 2024 Mar 15.
Artigo em Chinês | MEDLINE | ID: mdl-38500421

RESUMO

Objective: To analyze the causes and treatment of off target of the distal interlocking screws when short cephalomeduallry nails were installed through jig-guided targeting device, and to put forward the technical points to prevent off target. Methods: Retrospective analysis of 9 patients with intertrochanteric fractures treated between July 2014 and June 2023 was conducted, in which off target occurred during the insertion of the distal interlocking screw by jig-guided targeting device in short cephalomedullary nailling (<24 cm). There were 1 male and 8 females, with an average age of 82.7 years (range, 73-94 years). There were 3 cases of type A1, 5 cases of type A2, and 1 case of type A3 according to 2018-AO/Orthopaedic Trauma Association (AO/OTA) fracture classification. As for the misaligned distal interlocking screw, six parameters were collected and analyzed, including the time of finding, the position, the type of passing through the cortical bone, the special circumstances during operation (such as the need to remove the intramedullary nail for reaming the diaphysis, hammering, etc.), the treatment, and the patient follow-up results. Results: In the 9 patients, the off target of the distal interlocking screw was found in 7 cases during operation and in 2 cases after operation; the locking screw was located behind the nail in 7 cases and in front of the nail in 2 cases; the off target locking screw was passing tangentially in transcortical patern in 6 cases and in bicortical pattern through the medullary cavity in 3 cases. Three cases were attributed to the mismatch between the nail and the femur, two of which were attributed to the narrow femoral medullary cavity, one of which was attributed to the large anterolateral femoral bowing, and the other 6 cases were attributed to technical errors such as the loosening of the jig-guided targeting device, the tension of the fascia lata, and the blunt of the drill. In the 7 cases found during operation, the misaligned interlocking screw was removed first and the screw hole was left vacant, then in 2 cases, the interlocking screw was not used further; in 1 case, the distal dynamic hole was successfully inserted with a dynamic guide frame, and in 4 cases, the interlocking screw was successfully put after 2-3 attempts, leaving a large hole in the lateral cortex. No special treatment was performed in 2 cases found after operation. One patient was out of bed early after operation, 7 patients were in bed for 1 month, and 1 patient deteriorated to A3 type after operation and was in bed for 3 months. All the 9 patients were followed up 6-12 months, with an average of 8 months. Fracture healing was achieved in 8 patients. One patient with vacant interlocking screw had a secondary spiral fracture of the femoral shaft 3 months later, and was refixed with a long cephalomedullary nail and circlage wiring. Conclusion: Distal interlocking screw off target is rare, but when it occurs, it leaves a large cortical hole in the osteoporotic femoral shaft, reducing bone strength; the use of precision instruments and attention to technical details can reduce this adverse phenomenon.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Fraturas do Quadril , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pinos Ortopédicos , Parafusos Ósseos , Fraturas do Fêmur/cirurgia , Fêmur , Fixação Intramedular de Fraturas/métodos , Fraturas do Quadril/cirurgia , Fraturas do Quadril/etiologia , Estudos Retrospectivos , Resultado do Tratamento , Idoso
20.
J Int Med Res ; 52(3): 3000605241240946, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38534086

RESUMO

BACKGROUND: To compare the biomechanical stability of a novel, C-shaped nickel-titanium shape memory alloy (SMA) implant (C-clip) with traditional cerclage wiring in the fixation of a Vancouver B1 (VB1) periprosthetic femoral fracture (PFF). METHODS: In total, 18 synthetic femoral fracture models were constructed to obtain unstable VB1 fracture with an oblique fracture line 8 cm below the lesser trochanter. For each model, the distal portion was repaired using a 10-hole locking plate and four distal bi-cortical screws. The proximal portion was repaired using either three, threaded cerclage wirings or three, novel C-shaped implants. Specimens underwent biomechanical testing using axial compression, torsional and four-point bending tests. Each test was performed on three specimens. RESULTS: The C-clip was statistically significantly stronger (i.e., stiffer) than cerclage wiring in the three biomechanical tests. For axial compression, medians (ranges) were 39 (39-41) and 35 (35-35) N/mm, for the C-clip and cerclage wiring, respectively. For torsion, medians (ranges) were, 0.44 (0.44-0.45) and 0.30 (0.30-0.33) N/mm for the C-clip and cerclage wiring, respectively. For the four-point bending test, medians (ranges) were 39 (39-41) and 28 (28-31) N/mm; for the C-clip and cerclage wiring, respectively. CONCLUSION: Results from this small study show that the novel, C-shaped SMA appears to be biomechanically superior to traditional cerclage wiring in terms of stiffness, axial compression, torsion and four-point bending, and may be a valuable alternative in the repair of VB1 PFF. Further research is necessary to support these results.


Assuntos
Fraturas do Fêmur , Fraturas Periprotéticas , Humanos , Ligas de Memória da Forma , Fraturas do Fêmur/cirurgia , Fêmur/cirurgia , Fraturas Periprotéticas/cirurgia , Fixação Interna de Fraturas/métodos , Placas Ósseas , Fenômenos Biomecânicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...